Bran+Luebbe NOVADOS H5 Metering Pump

Electrical connection: 3ph; 230/400 V; 50/60 Hz; IP 55; ISO KL. F. Ambient temperature: 0°C at 40°C, product temperature: 0°C at 100°C. Gear type: integrated worm gear; reduction ratios: 28:1, 28:2, 33:2, 39:2, 44:2 ; resulting stroke frequency depends on motor type and mains frequency; lubrication: splash.

 


 
 

 

Weight, according to equipment (without motor) approx.415 - 545 kg
 

Flow Rate and Pressure for Single Pumps

Pumphead type

Diaphragm

Plunger

test

test

Material of displacement body
Housing material

PTFE
St. Steel / Plastic

St. Steel
St. Steel

Ceramic or St. Steel
St. Steel or Plastic

Flow rate at 200 min-1

max. operating pressure

Nozzle Size

l/h

GPM

bar 1)

PSI

bar 1)

PSI

bar 1)

PSI

0...81
0.356

-

-

-

-

500

7,252

8

0... 145

0.638

-

-

700

10,153

500

7,252

8

0... 226

0.994

-

-

500

7,252

500

7,252

15

0... 353

1.553

400

5,801

-

-

407

5,903

15

0... 509

2.24

283

4,105

-

-

283

4,105

15

0... 733

3.225

196

2,843

-

-

196

2,843

15

0... 997

4.387

144

2,089

-

-

144

2,089

15

0... 1414

6.222

102

1,479

-

-

102

1,479

25

0... 1773

7.801

81

1,175

-

-

81

1,175

25

0... 2174

9.566
66
975
-
66
957
25/40

0... 2615

11.506
55
798
-
-
55
798
25/40

0... 3181

13.996
45
653
-
-
45
653
25/40

0... 3802

16.728
38
551
-
-
38
551
40

0... 4580

20.152
31
450
-
-
31
450
40

0... 6842

30.105
21
305
-
-
21
305
40

0... 8836

38.878
16
232
-
-
16
232
50

0... 12722

55.977
-
-
-
11
160
65

0... 17318

76.199
-
-
-
8
116
80

0... 22618

99.519
-
-
6
87
80
 
 